Button-blocking command

The Button-blocking command is an event that enables you to block or unblock ceartain button gestures on a scanner connected to Gateway. This makes it impossible to scan any barcodes, receive certain button events, or take photos with the scanner until the block is resolved.
Use it in situations where the worker needs to perform an action outside of the regular workflow, like an acknowledgement of an error.
Depending on the blocking command, the button can be enabled again either by a predefined action of the worker or by sending the unblocking command.

Response: An Error event in case of error.

Name Type Description Accepted values Constraints Required
api_version string The input API schema version number. 1.0 Yes
event_type string The message type. trigger_block! Yes
event_id string The message identifier. This can be used to reference it. Any UUID format UUID format [0-9a-f]{8}-[0-9a-f]{4}-[0-9a-f]{4}-[0-9a-f]{4}-[0-9a-f]{12} Yes
time_created integer The time of creation client-side, used to determine the order of incoming messages. Unix time stamp in milliseconds. Any 1546300800000 <= value <= 99999999999999 Yes
device_serial string The serial number of a worker's device. Any 1 <= length <= 128 Yes
time_validity_duration integer The duration that the button should be blocked, in milliseconds. A value of 0 will block the button indefinitely (see Unblocking). Any value >= 0 No
trigger_block_gesture_list array [string] The list of buttons to block. If not provided or an empty list, the default is all acceptable values (see Unblocking). TRIGGER_SINGLE_CLICK TRIGGER_DOUBLE_CLICK TRIGGER_TRIPLE_CLICK 1 <= max items < 15 No
trigger_unblock_gesture_list array [string] The list of triggers that unblock the blocked buttons. If not provided or an empty list, unblocking is not possible via a button (see Unblocking). TRIGGER_SINGLE_CLICK TRIGGER_DOUBLE_CLICK TRIGGER_TRIPLE_CLICK 1 <= max items < 15 No
trigger_block_state boolean The state of the buttons (true for blocking and false for unblocking). true or false Yes

How to block buttons

When the trigger_block_state field is set to true, the Gateway will block the button gestures that are in the trigger_block_gesture_list list for the specified connected device.

If trigger_block_gesture is not given or empty, all buttons will be blocked.

How to unblock buttons

  • When the trigger_block_state field is set to false, the Gateway will unblock all the buttons for the specified connected device.
  • When the trigger_block_state field is set to true, a list of triggers to unblock the blocked buttons can be provided via trigger_unblock_gesture_list. The worker is then able to unblock a button on their own. This can be used to require a confirmation.
  • When the trigger_block_state field is set to true, a blocking timeout can be provided via time_validity_duration. After the time has elapsed, all blocked button are unblocked.

Unblocking

If no unblocking command is sent, the button will be unblocked by:

  • Pairing to another connectivity device
  • Intentionally disconnecting (scanning PEP barcode or pressing button in Insight Mobile)
  • Being out of range for long enough until the scanner stops advertising to reconnect (default 3 minutes)
  • Scanner being put back into the charger
  • Hard reset.

Examples

Block the single-press button

{
  "api_version": "1.0",
  "event_type": "trigger_block!",
  "event_id": "02114da8-feae-46e3-8b00-a3f7ea8672df",
  "time_created": 1546300800000,
  "time_validity_duration": 60000,
  "device_serial": "M2MR111100928",
  "trigger_block_gesture_list": ["TRIGGER_SINGLE_CLICK"],
  "trigger_block_state": true
}

Block all buttons

{
  "api_version": "1.0",
  "event_type": "trigger_block!",
  "event_id": "02114da8-feae-46e3-8b00-a3f7ea8672df",
  "time_created": 1546300800000,
  "device_serial": "M2MR111100928",
  "trigger_block_gesture_list": [],
  "trigger_block_state": true
}

Unblock all buttons

{
  "api_version": "1.0",
  "event_type": "trigger_block!",
  "event_id": "02114da8-feae-46e3-8b00-a3f7ea8672df",
  "time_created": 1546300800000,
  "device_serial": "M2MR111100928",
  "trigger_block_state": false
}

Block scanning until the worker confirms with a double-press

{
  "api_version": "1.0",
  "event_type": "trigger_block!",
  "event_id": "02114da8-feae-46e3-8b00-a3f7ea8672df",
  "time_created": 1546300800001,
  "device_serial": "MDMR102001603",
  "trigger_block_gesture_list": ["TRIGGER_SINGLE_CLICK"],
  "trigger_unblock_gesture_list": ["TRIGGER_DOUBLE_CLICK"],
  "trigger_block_state": true
}